AC Size Calculator (BTU)

Enter the room size and a few details about it. You get the cooling load in BTU and the stock air conditioner size to buy, based on the ENERGY STAR sizing chart.

Your room

1. Room size
Room length
ft
in
Room width
ft
in
Ceiling height
2. ConditionsSun

Buy

6,000 BTU

nearest stock size

Cooling load

6,000 BTU

after adjustments

Room

180 sq ft

chart: 6,000 BTU

Tons

0.5

12,000 BTU = 1 ton

Where your room lands

Window or portable unit
15' x 12' · 8 ft ceiling5k12k18k24k36k6,000 BTU

The green bar is the cooling load; the yellow dot is the unit size to buy. Bigger is not better — buy the size that matches the load.

ENERGY STAR sizing chart

Room areaCapacity
100–150 sq ft5,000 BTU
150–250 sq ft6,000 BTU
250–300 sq ft7,000 BTU
300–350 sq ft8,000 BTU
350–400 sq ft9,000 BTU
400–450 sq ft10,000 BTU
450–550 sq ft12,000 BTU
550–700 sq ft14,000 BTU
700–1,000 sq ft18,000 BTU
1,000–1,200 sq ft21,000 BTU
1,200–1,400 sq ft23,000 BTU
1,400–1,500 sq ft24,000 BTU
1,500–2,000 sq ft30,000 BTU
2,000–2,500 sq ft34,000 BTU

Shopping list

  • ✓Air conditioner: 6,000 BTU (0.5 ton) — window or portable unit
  • ✓ENERGY STAR certified model (look for the CEER rating on the yellow EnergyGuide label)
  • ✓Window: measure the opening width and height before ordering; most units list a minimum and maximum
  • ✓Foam weatherstrip for the gaps around a window or portable unit

For a whole house or a central system, an HVAC contractor should run an ACCA Manual J calculation. This planner sizes one room.

How many BTU per square foot?

ENERGY STAR's sizing chart starts at 5,000 BTU for 100–150 sq ft and works out to roughly 20 BTU per square foot for typical rooms. A 12' x 15' bedroom (180 sq ft) needs about 6,000 BTU; a 450–550 sq ft living room needs about 12,000 BTU. The full chart is printed under the planner.

Adjustments

Why bigger isn't better

An oversized air conditioner cools the room quickly and then shuts off before it has run long enough to pull moisture out of the air. The room ends up cold and damp, and the short on-off cycles waste energy and wear out the compressor. Pick the stock size closest to the load; if the next size up is much bigger, a variable-speed (inverter) unit handles the extra capacity better.

Window, portable or mini-split?

Window units cover most single rooms up to about 12,000 BTU and are the most efficient for the money. Portable units are easiest to install but lose some cooling through their exhaust hose, so many people size them up. For larger rooms, or to cool and heat quietly, a ductless mini-split is the better choice. Check the electrical, too: units over about 14,000 BTU often need a 230-volt outlet.

BTU and tons

One ton of cooling is 12,000 BTU per hour. A 24,000 BTU mini-split is a 2-ton system. For a whole house or a central system, have an HVAC contractor run an ACCA Manual J load calculation — it accounts for windows, insulation and climate, which a single-room chart can't.

Sources: ENERGY STAR — room air conditioners.